TUE1A060A9361A. Trane … You can easily identify the nominal size of your Trane Air Conditioner and Heat Pump through checking out the model number. 2 Tons 3 Tons 4 Tons 5 Tons. Within this string of letters and numerals, you should find an even, two-digit number.
4TTZ0024A1 4TTZ0036A1 4TTZ0048A1 4TTZ0060A1. Where to find Trane AC Tonnage? Trane XL16i: MODEL.
Capacity: Look for those elusive two digits in the model number (usually, but not always) divisible by 6 and divide by 12 to convert to tons. We also install Trane residential furnaces and air conditioners. You should look for the last two numbers of the first numbers after a cluster of letters at the beginning of the model number.
They have model numbers that tell everything from the size of the unit to whether the system has had major upgrades.The easiest way to look Trane tonnage model number is on the AC unit itself. Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 … TUE1C100A9481A. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12.
$600 $740 $980 $1230 *Original Cooling Cost is 50% More or Higher Per Year With An Old System! 1.5 Tons 2 Tons 2.5 Tons 3 Tons 3.5 Ton 4 Ton 5 Ton. TUE1D120A9601A. This is equivalent to 12,000 Btu/hr.In some cases, bigger size is better. In determining the capacity of heating and air conditioning system, the term btu (British Thermal Units) is used.
Our samples have been simplified to concentrate more on the location of each individual units tonnage and air flow characteristics. Within this string of letters and numerals, you should find an even, two-digit number.The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12. Trane uses their model number to identify its use in the The Trane Model Identification Number of a product is often featured prominently on the packaging of said product. RLA is an acronym for Rated Load Amperage, and is what the maximum amperage should be when the condenser up and running. Here at With more than 10 years experience in Heating and Air Conditioning System. MODEL. But when it comes to air conditioners, in some cases less is more. If you have any problem, please contact your local dealer or Trane sales office.I have a old RTU and the model number is SFHC-B306-LB. This means the rate of heat transfer needed to freeze 1 ton of water in 24 hours. Sample Model #: 5 8 1 B E V 0 9 0 1 8 0 Digits 1,2,3,4: Digits 10, 11, 12: BTUH Input Product Series, for example: 115 115,000 Input 581B = 3 to 12.5 ton Gas/Elec 180 180,000 Input Digits 5: Voltage Indicator: Digits 7,8,9: Tonnage: E 460-3-60 036 3-tons J 208/240-1-60 048 4-tons P 208/240-3-60 060 5-tons T 575/3/60 072 6-tons 090 7.5-tons You should never simply buy the biggest AC unit possible, or you could end up with an oversized system.You should look for the last two numbers of the first numbers after a cluster of letters at the beginning of the Trane is the only brand we are familiar with that occasionally lists a two-digit number for the thousands of BTU rating that is not divisible by 6 or 12—but close.Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). We helped hundreds of homeowners to find the proper heating and air conditioning solutions. TUE1B080A9361A. The SEER number is calculated by dividing the cooling output for a typical cooling season by the total electric energy input during the same timeframe. The wrong choice could leave you saddled with never-ending headaches and ever-high bills. (a description is not listed) C: Downflow Economizer and Oversize Motor C: Minor Design Sequence A: Service Digit (i don’t know exactly what this means)Trane RTU model # SXHEC9040E76AD8D3D01GGNRTX S= Self Contained X= DX cooling,Extended Casing H= Single Zone E= 5th Developement sequence C90= 90 Tons 4= 460/60/3 XL 0= No Heat E= Design Sequence 7= 100% Exhaust w/ statitrac & 15 hp motor 6= Ex fan Drive 600 RPM A= Throw away filters D= Supply Fan HP 40 ( 2-20HP) 8= Supply Fan Drive 800 RPM D= !00% Economizer 3= VAV ( SA temp Control w/ IG Vanes) D= BAYSENS014 O= Standard Ambient Control 1= UL ApprovalTTP018—1-1/2ton TTP024—2 ton TTP030—2 1/2 yon TTP036—3 ton TTP042—3 1/2 ton TTP048—4 tonTWE030C140b0 TW – split component heat pump compatable E – Electric furnace (like they said, heat strips are added in the field, could be anything from 10kw to 25 kw) 0 – Brazed refrigeration connection 30 is 2.5 ton like you mentioned C – Major development sequence C is standard system, E would be VS motor, P would be high eff system 1 – 220-230/1/60 (electric rating) 4 – Accurtron flow control check valve 0 – Standard insulation B – Minor design sequence (means nothing other than to the facotory) 0 – Service digit (they change these as they do “improvements” on thier stuff)Trane model number nomenclature split into several segments. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. MODEL. The model number descriptions listed in this blog are for Trane furnaces with the below model numbers . Trane XB80 Single Stage Gas Furnace – Upflow/Horizontal. One ton of cooling is the rate of heat transfer needed to freeze 2,000 lbs – or one ton – of water in 24 hours. With a simple understanding of BTU to tonnage then interpreting the trane tonnage from model numbers will be easy.Trane uses model numbers incorporate the BTU equivalent into their unit model numbers, or reference the tonnage.
TONS.