Size 32 and above:- 1 per kit, with exception of CMP size 32 which contains 2 per kit. Standards: Generally to BS6121: Part 1: 2005. Click here for more information. For Group I mining applications see the A2F100. Aluminium Wire Armour, it may be necessary to consider an alternative Cable Gland material, e.g. ** When CMP installation accessories are used. Technical Resources We have gathered together a number of technical resources for use as reference on electrical projects. Cable Gland Kit Cable gland kits are composed of all the parts needed to fit a cable gland securely into the electrical cables. Our Product Finder tool allows you to find the perfect product for your requirements. Brass CX Type Cable Glands. Helping you find the right cleat for your application. We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below. Further technical information can be found here. ADE 1F Cable Entry CCH Hawke CMP Peppers BICC/Prysmian CCG Sealing Range* Thread ADE 1F 501/421 A2F A2LF A2EX A2F 4.0 - 8.0 mm M12 CAP816404 NA NA NA NA NA M16 CAP816594 501/421/Os/M16 NA NA 494AB51 054116/M16 Used in applications where it is essential to provide an IP66 seal or an explosion proof seal (certified version) on the outer sheath. A2 Cable Glands – Unarmoured & Braid Armoured Cables CMP A2 Cable Glands. Use the table below to assist in gland size selection for your cable. Brass CW Cable Glands. For example, if your cable bundle diameter is 50mm means then you should select the 50MM cable gland only. Brass Marine Cable Glands. • Globally marked, IECEx, ATEX & CSA. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. lead sheathed cable). E1W = E1W cable glands with IP66 seals on inner and outer cable sheath. Below is the double compression cable gland size chart: Double compression cable gland. Cable Gland Chart Size Pg63 Gland Brass Cable Gland Brass EMC Cable Gland Chart Size IP68 With Dust Cover 15mm Thread Length PG/Metric US $0.26-$9.99 / Piece 1000.0 Pieces (Min. Each cable gland type has sub-sets: e.g. Alternatively, view our full range of cable glands here. *If the cable armour is of a non-standard material, e.g. Refer to Maintaining a Seal for further information. Nickel Plating, The type and size of the cable entry hole in the mating electrical equipment, The wall thickness of the enclosure or gland plate, as a longer cable gland thread may be required, The ingress protection rating of the electrical equipment or site standard required to be maintained, Whether a single seal or double seal Cable Gland is required, If an entry thread sealing washer is required to meet the ingress protection rating, Is there is a deluge protection requirement ‘D’, If fixing accessories such as locknuts and serrated washers are required, If an earth tag or grounding locknut is required**, If a thread conversion adaptor/reducer is required to complete the installation, If any stopper plugs are required to close unused cable entries. CMP ProductsT3CDS (Triton Cable Gland) Installation Video- Direct Make Off- SWA Armour Brass Wiping Cable glands. T3CDS Cable Gland SWA, STA and Wire Braid Cable Ordering Information Cable Connec-tor Size Available Entry Threads ‘C’ Minimum Thread Length ‘E’ Cable Bedding Diameter ‘A’ Overall Cable Diameter ‘B’ Armour Range † Across Flats ‘D’ Across Cor-ners ‘D’ Nominal Protrusion Length ‘F’ NPT Catalog Number Metric Catalog Number Cable Gland SECURE CABLE GLAND SELECTION CHART. Call us today on +44 191 265 7411. These CMP accessories may be critical to the safety of the installation and overall performance, it is vital that the CMP accessories are correctly specified and installed. Call one of our team now on, 737 | Thread Conversions | Adaptors & Reducers, 797 | Male to Male or Female to Female Adaptor, PX784REX | 45 Degree RapidEx Barrier Union, PX789REX | 90 Degree RapidEx Barrier Union, IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, C22.2 No 0,0.4, 94, 174, CAN/CSA-E60079-0,1,7,15, Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium, CMP SOLO LSF Halogen Free Thermoset Elastomer, Unarmoured & Braided when terminated inside enclosure, Dimensions are in inches unless otherwise stated, Available Entry Threads 'C' (Alternate Metric Thread Lengths Available), Dimensions are displayed in millimetres unless otherwise stated, A2F Cable Gland for Explosive Atmosphere |. Brass Metric Strain Relief Cable Glands. Alternatively, please contact us. The CCG industrial cable glands range is extensive and covers just about every size and type of armoured and unarmoured cables for every kind of cable gland installation… Read more. Cable gland size chart: Cable gland size is equal to the size of the cable bundle diameter. • Deluge protected Type Commercial/ Medium Duty Heavy Duty W/P / FLP Flange Type 14.5 PBC 5/8” PBCH 3 PBW 01S PBF 5 15.5 PBC 3/4” PBCH 3 PBW 01S PBF 4 SELECTION CHART FOR POLYCAB CABLE GLANDS FOR XLPE INSULATED ARMOURED CABLE SELECTION CHART FOR POLYCAB CABLE GLANDS FOR XLPE INSULATED ARMOURED CABLE Cable O.D. Our Product Finder tool allows you to find the perfect product for your requirements. Gland Chart for BS6724 Booklet Cables Size/No of cores 1.5mm² stranded 2.5mm² stranded 4mm² 6mm² 10mm² 16mm² Gland Cleat 2 20s/20ss 15-1B 20S/20ss 15-1B 20s 15-1B 20 15-2B 20 15-2B 25 15-2B 3 20s/20ss 15-1B 20s 15-1B 20s 15-1B 20 15-2B 20 15-2B 25 15-2B These glands are designed to accommodate a wide variety of cable diameters, from approximately 2mm-63mm / 0.08-2.50”, and most models are IP68 rated, meaning that they can be immersed in matter and still maintain a liquid-tight seal. Cookies are tiny text files stored on your device that allow data states to be tracked as you browse around a site. Type Double Comp. Order) LSOH Glands. Cable glands are often named to describe their function, e.g. Compatibility of material selection, short circuit rating (in the case of earth tags and grounding locknuts) and sealing performance (in the case of sealing washers) cannot be guaranteed if accessories from other sources are used. Approvals: LUL Approval Number R00131. E1FX, E1FW. CW Cable Glands specification. Call us today on +44 191 265 7411. Identify the type of cable to be used. SWA Cable Gland and Cleat Selection Chart SWA Gland Size Chart (BW and CW Glands) Cable Cleat Size Chart Nominal Cross Number of Cores Sectional Area mm2 1.5- - 20S-20S 20S 20S2020 25S 20S2532 32 2.5- - 20S20S- 20S 2020 25S 25S25 32 32 40 4.0- - 20S20- 2020 25S 3232 32 40 - - 6.0- - 2020 - 20 10.0- - 2020 25S- 16.0- -25S25 - 25 **For certain medium voltage and high voltage cables, with higher fault rate levels, CIEL Cable Glands, which have been tested for higher SCC faults may be required. With a wide variety of electrical cable glands available to suit IEC, NEC and CEC wiring codes, products can be used within a large number of applications – including oil and gas, petrochemical, construction, pharmaceutical, transportation and mining to name a few. A2, CMP brass cable gland to BS6121. The cable gland, cable cleat and accessories specialist | In order to maintain product warranty it is vital that genuine CMP accessories are used for installation of CMP cable glands. Click here for more information. The cable gland, cable cleat and accessories specialist | Call us today on +44 191 265 7411 Coronavirus notice: We are monitoring the situation with COVID-19 & have measures in … Globally Approved, Explosive Atmosphere Cable Gland, • Displacement type flameproof seal The following steps, together with the information throughout our cable gland catalogue, will ensure that the CMP cable gland size and specification selected will be fit for purpose and perform optimally. Aluminium. • -60°C to +130°C The cable gland, cable cleat and accessories specialist | Cable Gland Sizes Chart PG9 to PG48. Brass PG Cable Glands. CABLE GLAND SIZE CHART ; Conductor Size (mm 2): No. Cable Gland Size. The two most commonly used cable glands are the … Coronavirus notice: We are monitoring the situation with COVID-19 & have measures in place. Global Cable Gland Solutions - ADE 1F * All dimensions are shown in inches unless noted. Cable Glands | Cleveland Cable Company. CABLE SPEC. These cable gland insert could also be utilized with either PG or metric cable glands as well as strain reliefs that range from M16 to M50 and PG7 to PG21. cable size and gland size chart with hole cutter size good information. No thanks, I'd just like to Download the datasheet. These cable gland size table will surely help you know the different sizes of different types of cable glands. In the next chapter, we will present you essential information on how to perform cable gland size calculation excel the proper and simple way. Cable Gland Sizes: Selecting Correctly. Alternatively, view our full range of cable glands here. 737 | Thread Conversions | Adaptors & Reducers, 797 | Male to Male or Female to Female Adaptor, PX784REX | 45 Degree RapidEx Barrier Union, PX789REX | 90 Degree RapidEx Barrier Union, Cable Glands permitted under NEC & CEC wiring rules, Certification to IEC 60079 based standards, Typical Class I Div 1 & 2 Sealing Methods, Typical Class I Zone 1 & 2 Sealing Methods, Typical Class I Zone 2 & Safe Area Sealing Methods, Cable Gland Types for Explosive Atmospheres, Cable Gland Sizes: Selecting the Right Gland, Check the construction, size and material properties of the cable, Check the size of the overall cable diameter, Short circuit fault current rating of the cable armour**, Diameter of the inner bedding (where present), Diameter of the lead covering (where present), Size and type of armour or braid (where present), Any special environmental requirements in relation to corrosion protection, The material of the mating electrical enclosures to eliminate dissimilar metals where possible or if required, Whether any protective plating or coating is required to be applied to the Cable Gland, e.g. For Armoured SINGLE Core Power Cables Type AYFY & AYWY 650 / 1100 V. No of Cores X SQUARE MM APPROX Overall Dia. Cable Gland Selection Chart. of Cable Medium Duty SC TYPE Nipple Entry for Medium Duty HEAVY DUTY SCG AS PER IS 12943: Nipple Entry in Metric Flange Type GLAND : Weather Proof(SWP) as per BS 6121 IS/IEC 60529-2001 FlameProof (SFP)asperBS 6121 … Helping you find the right cleat for your application. A2 cable glands manufactured from high quality durable materials; Robust, heavy duty design; Displacement type seal-60˚C to +130˚C (standard), -20˚C to 200˚C (ThermIn) Deluge protected A2 cable gland; Order Code: CMP … In addition to entry thread sealing washers, CMP also provides standard locknuts, grounding locknuts, earth tags, serrated washers and shrouds as required, which should be used as appropriate to the installation standard or equipment configuration. Accessories are not typically included with the cable glands as standard, unless a cable gland pack/kit is ordered. The gland sizes recommended in this chart are for guidance only and are based on cables manufactured to BS 5467. of Cores: Approx. DOUBLE CORE Single Comp. Overall Diameter (mm) When the cable is armoured, check the following in addition: Understanding the intended installation for the Cable Gland, check the following: For installations in explosive atmospheres, special considerations should be taken into account to ensure compliance with national or international standard codes of practice. Cable Gland & Cable Cleat Selector Chart Download as PDF WARNING: Whilst all due care has been taken in compiling this chart, it is for guidance only. Cable Gland Size: Available Entry Threads 'C' Overall Cable Diameter 'A' Across Flats 'D' Across Corners 'D' Protrusion Length 'F' Combined Ordering Reference (*Nickel Plated Brass NPT) Shroud: Cable Gland Weight (ozs) NPT: NPT (Option) Metric (Option) Thread Length (NPT) 'E' Min: Max: Max: Max: Max: Size: Type: Ordering Suffix: 20S16: ½" ¾" M20: 0.78: 0.13: 0.34: 0.95: 1.04: 1.04: 20S16: A2F: 1RA531 Brass A2 Type Cable Glands. Cable Gland Type Size Thread Material (Optional) 501/421/R C M32 Brass S 501/421/R C 1 ¼ " NPT Brass S Technical Data Flameproof Exd and Increased Safety Exd IIC Gb, Exe IIGb, Extb IIIC Db, II 2 GD Certifi cate No’s: Baseefa 06ATEX0056X and IECEx BAS06.0013X. GLANDS ACCESSORIES The recommendations above are given in good faith but the dimensions of cables may vary with manufacturing tolerances and we advise that the cable diameter is measured where possible before purchasing components. *** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request, Want to discuss this product with one of the CMP Technical Team? Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
This site uses cookies. Coronavirus notice: We are monitoring the situation with COVID-19 & have measures in place. Brass E1W Cable Glands. The metric thread cable gland is one of the most popular types of cable glands, the dimensions ranging from M6 to M100, which means the hole size in mm must be exactly same like this size chart.. Cable Glands size chart. SWA Cable Gland Chart: Cable Size: 1 Core: 2 Core: 3 Core: 4 Core: 5 Core: 7 Core: 12 Core: 19 Core: 27 Core: 37 Core: 48 Core: 1.5mm² - 20S 20S 20S 20S 20 25 25 32 32 32 2.5mm² - 20S 20S 20S 20 20 25 25 32 40 40 4.0mm² - 20S 20S 20 20 20 25 32 40 40 50 6.0mm² - 20 20 20 20 25 - - - - - 10.0mm² - … CMP designs and manufactures electrical armoured and unarmored cable glands for use in industrial & explosive atmospheres. CMP cable glands robust and heavy duty in desgin; Metal-to-metal armour clamping; Controlled outer ‘load retention’ seal; Unique OSTG prevents overtightening-60˚C to +130˚C (standard), -20˚C to 200˚C (ThermIn) temperature range ; Deluge protected CW cable gland; EMC tested CW cable gland; Order Code: CMP CW** (Brass) CW Cable Glands. If you would like further information regarding this product, please complete the form below.